Modbus POE ETH Relay 8(B)
Waveshare · Miscellaneous
IntroStudioStudio MAXCOREXM
First appeared in Studio 4.2.0.17 and CORE 1.1.0.54
Modbus POE ETH Relay 8(B) is a module from Waveshare. Control Waveshare Relay.
Device settings
- IP AddressTextDefault: 192.168.0.1Network address of the relay unit.
- PortNumber1 to 99999Default: 4196Network port of the relay unit.
Commands (4)
Summary table
| Command | Type | Parameters |
|---|---|---|
| Set Relay On | Button | Relay Number |
| Set Relay Off | Button | Relay Number |
| Toggle Relay | Button | Relay Number |
| Flash Relay | Button | Relay Number, Invert |
Set Relay OnButton
Switches the chosen relay on.
- Relay NumberNumber1 to 8Default: 1Which relay to switch, from 1 to 8.
Set Relay OffButton
Switches the chosen relay off.
- Relay NumberNumber1 to 8Default: 1Which relay to switch, from 1 to 8.
Toggle RelayButton
Switches the chosen relay to the opposite of its current state.
- Relay NumberNumber1 to 8Default: 1Which relay to switch, from 1 to 8.
Flash RelayButton
Switches the chosen relay while the button is held, with an option to reverse it.
- Relay NumberNumber1 to 8Default: 1Which relay to switch, from 1 to 8.
- InvertOn/OffDefault: OffReverses the relay action between normally closed and normally open.
Triggers (8)
Summary table
| Trigger | Conditions |
|---|---|
| Input 1 Changed | Input Closed |
| Input 2 Changed | Input Closed |
| Input 3 Changed | Input Closed |
| Input 4 Changed | Input Closed |
| Input 5 Changed | Input Closed |
| Input 6 Changed | Input Closed |
| Input 7 Changed | Input Closed |
| Input 8 Changed | Input Closed |
Input 1 Changed
Fires when input 1 closes or opens.
- Input ClosedOn/OffDefault: OnOn for when the input closes, off for when it opens.
Input 2 Changed
Fires when input 2 closes or opens.
- Input ClosedOn/OffDefault: OnOn for when the input closes, off for when it opens.
Input 3 Changed
Fires when input 3 closes or opens.
- Input ClosedOn/OffDefault: OnOn for when the input closes, off for when it opens.
Input 4 Changed
Fires when input 4 closes or opens.
- Input ClosedOn/OffDefault: OnOn for when the input closes, off for when it opens.
Input 5 Changed
Fires when input 5 closes or opens.
- Input ClosedOn/OffDefault: OnOn for when the input closes, off for when it opens.
Input 6 Changed
Fires when input 6 closes or opens.
- Input ClosedOn/OffDefault: OnOn for when the input closes, off for when it opens.
Input 7 Changed
Fires when input 7 closes or opens.
- Input ClosedOn/OffDefault: OnOn for when the input closes, off for when it opens.
Input 8 Changed
Fires when input 8 closes or opens.
- Input ClosedOn/OffDefault: OnOn for when the input closes, off for when it opens.