Modbus POE ETH Relay 8(B) is a module from Waveshare. Control Waveshare Relay.

Device settings​

  • IP AddressTextDefault: 192.168.0.1Network address of the relay unit.
  • PortNumber1 to 99999Default: 4196Network port of the relay unit.

Commands (4)​

Summary table
CommandTypeParameters
Set Relay OnButtonRelay Number
Set Relay OffButtonRelay Number
Toggle RelayButtonRelay Number
Flash RelayButtonRelay Number, Invert
Set Relay OnButton

Switches the chosen relay on.

  • Relay NumberNumber1 to 8Default: 1Which relay to switch, from 1 to 8.
Set Relay OffButton

Switches the chosen relay off.

  • Relay NumberNumber1 to 8Default: 1Which relay to switch, from 1 to 8.
Toggle RelayButton

Switches the chosen relay to the opposite of its current state.

  • Relay NumberNumber1 to 8Default: 1Which relay to switch, from 1 to 8.
Flash RelayButton

Switches the chosen relay while the button is held, with an option to reverse it.

  • Relay NumberNumber1 to 8Default: 1Which relay to switch, from 1 to 8.
  • InvertOn/OffDefault: OffReverses the relay action between normally closed and normally open.

Triggers (8)​

Summary table
TriggerConditions
Input 1 ChangedInput Closed
Input 2 ChangedInput Closed
Input 3 ChangedInput Closed
Input 4 ChangedInput Closed
Input 5 ChangedInput Closed
Input 6 ChangedInput Closed
Input 7 ChangedInput Closed
Input 8 ChangedInput Closed
Input 1 Changed

Fires when input 1 closes or opens.

  • Input ClosedOn/OffDefault: OnOn for when the input closes, off for when it opens.
Input 2 Changed

Fires when input 2 closes or opens.

  • Input ClosedOn/OffDefault: OnOn for when the input closes, off for when it opens.
Input 3 Changed

Fires when input 3 closes or opens.

  • Input ClosedOn/OffDefault: OnOn for when the input closes, off for when it opens.
Input 4 Changed

Fires when input 4 closes or opens.

  • Input ClosedOn/OffDefault: OnOn for when the input closes, off for when it opens.
Input 5 Changed

Fires when input 5 closes or opens.

  • Input ClosedOn/OffDefault: OnOn for when the input closes, off for when it opens.
Input 6 Changed

Fires when input 6 closes or opens.

  • Input ClosedOn/OffDefault: OnOn for when the input closes, off for when it opens.
Input 7 Changed

Fires when input 7 closes or opens.

  • Input ClosedOn/OffDefault: OnOn for when the input closes, off for when it opens.
Input 8 Changed

Fires when input 8 closes or opens.

  • Input ClosedOn/OffDefault: OnOn for when the input closes, off for when it opens.